This driver synchronizes the computer time using the Inter-Range Instrumentation Group (IRIG) standard time distribution signal. This signal is generated by several radio clocks, including those made by Arbiter, Austron, Bancomm, Odetics, Spectracom, Symmetricom and TrueTime, among others, although it is often an add-on option. The signal is connected via an optional attenuator and cable to either the microphone or line-in port of a workstation or PC.
The driver requires an audio codec or sound card with sampling rate 8 kHz and m-law companding to demodulate the data. This is the same standard as used by the telephone industry and is supported by most hardware and operating systems, including Solaris, FreeBSD and Linux, among others. In this implementation, only one audio driver and codec can be supported on a single machine. In order to assure reliable signal capture, the codec frequency error must be less than 250 PPM (.025 percent). If necessary, the tinker codec configuration command can be used to bracket the codec frequency to this range.
For proper operation the IRIG signal source should be configured for analog signal levels, not digital TTL levels. In most radios the IRIG signal is driven ±10 V behind 50 Ohms. In such cases the cable should be terminated at the line-in port with a 50-Ohm resistor to avoid overloading the codec. Where feasible, the IRIG signal source should be operated with signature control so that, if the signal is lost or mutilated, the source produces an unmodulated signal, rather than possibly random digits. The driver automatically rejects the data and declares itself unsynchronized in this case. Some devices, in particular Spectracom radio/satellite clocks, provide additional year and status indication; other devices may not.
In general and without calibration, the driver is accurate within 500 ms relative to the IRIG time. After calibrating relative to the PPS signal from a GPS receiver, the mean offset with a 2.4-GHz P4 running FreeBSD 6.1 is less than 20 ms with standard deviation 10 ms. Most of this is due to residuals after filtering and averaging the raw codec samples, which have an inherent jitter of 125 ms. The processor load due to the driver is 0.6 percent on the P4.
However, be acutely aware that the accuracy with Solaris 2.8 and beyond has been seriously degraded to the order of several milliseconds. The Sun kernel driver has a sawtooth modulation with amplitude over 5 ms P-P and period 5.5 s. This distortion is especially prevalent with Sun Blade 1000 and possibly other systems.
The driver performs a number of error checks to protect against overdriven or underdriven input signal levels, incorrect signal format or improper hardware configuration. The specific checks are detailed later in this page. Note that additional checks are done elsewhere in the reference clock interface routines.
This driver incorporates several features in common with other audio drivers such as described in the Radio CHU Audio Demodulator/Decoder and the Radio WWV/H Audio Demodulator/Decoder pages. They include automatic gain control (AGC), selectable audio codec port and signal monitoring capabilities. For a discussion of these common features, as well as a guide to hookup, debugging and monitoring, see the Reference Clock Audio Drivers page.
The IRIG signal format uses an amplitude-modulated carrier with pulse-width modulated data bits. For IRIG-B, the carrier frequency is 1000 Hz and bit rate 100 b/s; for IRIG-E, the carrier frequenchy is 100 Hz and bit rate 10 b/s. While IRIG-B provides the best accuracy, generally within a few tens of microseconds relative to IRIG time, it can also generate a significant processor load with older workstations. Generally, the accuracy with IRIG-E is about ten times worse than IRIG-B, but the processor load is somewhat less. Technical details about the IRIG formats can be found in IRIG Standard 200-98.
The driver processes 8000-Hz m-law companded samples using separate signal filters for IRIG-B and IRIG-E, a comb filter, envelope detector and automatic threshold corrector. An infinite impulse response (IIR) 1000-Hz bandpass filter is used for IRIG-B and an IIR 130-Hz lowpass filter for IRIG-E. These are intended for use with noisy signals, such as might be received over a telephone line or radio circuit, or when interfering signals may be present in the audio passband. The driver determines which IRIG format is in use by sampling the amplitude of each filter output and selecting the one with maximum signal.
Cycle crossings relative to the corrected slice level determine the width of each pulse and its value - zero, one or position identifier (PI). The data encode ten characters (20 BCD digits) which determine the second, minute, hour and day of the year and with some IRIG generators the year and synchronization condition. The comb filter exponentially averages the corresponding samples of successive baud intervals in order to reliably identify the reference carrier cycle.
A type-II phase-lock loop (PLL) performs additional integration and interpolation to accurately determine the zero crossing of that cycle, which determines the reference timestamp. A pulse-width discriminator demodulates the data pulses, which are then encoded as the BCD digits of the timecode. The timecode and reference timestamp are updated once each second with IRIG-B (ten seconds with IRIG-E) and local clock offset samples saved for later processing. At poll intervals of 64 s, the saved samples are processed by a median filter and used to update the system clock.
00 00 98 23 19:26:52 2782 143 0.694 10 0.3 66.5 3094572411.00027
If clockstats is enabled, the most recent line is written to the clockstats file every 64 s. If verbose recording is enabled (fudge flag 4) each line is written as generated.
The first field containes the error flags in hex, where the hex bits are interpreted as below. This is followed by the year of century, day of year and time of day. Note that the time of day is for the previous minute, not the current time. The status indicator and year are not produced by some IRIG devices and appear as zeros. Following these fields are the carrier amplitude (0-3000), codec gain (0-255), modulation index (0-1), time constant (4-10), carrier phase error (0±0.5) and carrier frequency error (PPM). The last field is the on-time timestamp in NTP format.
The error flags are defined as follows in hex: